• @unmagical@lemmy.ml
    link
    fedilink
    2856 months ago

    Regardless of whether or not the parents were around the ability for a body to be forcibly pulled into the machinery is an obvious failure in operating a safe pool.

    • @Wogi@lemmy.world
      link
      fedilink
      1506 months ago

      It’s a failure on a number of levels, failure to maintain a safe pool, AND failure to maintain a safe working environment.

      And honestly the employee refusing to review security footage until the police showed up when a child was missing with the fuck?

        • @Yawweee877h444@lemmy.world
          link
          fedilink
          456 months ago

          Yeah maybe but it could also be someone desparate in a shitty low pay job who is afraid of getting fired. Just saying, not enough info

          • @madcaesar@lemmy.world
            link
            fedilink
            306 months ago

            That just sounds like “I was only following orders!” a child is missing FFS, look at the footage and fuck the corporation.

            • @kandoh@reddthat.com
              link
              fedilink
              146 months ago

              Yeah, even if you’re half starved and are certain the company will retaliate… That’s still a little child. You’ve got to take the hit.

    • @Duamerthrax@lemmy.world
      link
      fedilink
      436 months ago

      This has been a known problem for decades. I remember watching videos about it on Discovery channel back when they still ran education content. One case, a person had their intestines sucked out.

      The solution has always been to have multiple intakes for the suction line and have the kill switch in clear view of the pool.

    • @bcgm3@lemmy.world
      link
      fedilink
      34
      edit-2
      6 months ago

      You can say that again. Growing up in Florida, I’ve been in a lot of swimming pools and water parks, and I have never seen anything like what is shown in the video attached to this article. That opening is huge. user224’s link says the pipe is 30cm (almost a foot) in diameter. Even in giant public pools I’ve been in, I can’t recall seeing an opening or fixture that size. That, coupled with a lack of any cover on it, seems so obviously dangerous. God, what an awful way to go.

      • @lennybird@lemmy.world
        link
        fedilink
        English
        12
        edit-2
        6 months ago

        Seems like litigation is still ongoing but most recent articles I’ve read state that pump was either recently repaired or replaced, and flow was in the wrong direction. If it was outflow, nobody could swim in there if they wanted to (but if it was off, a small child still could, so a grate still should’ve been on there). They suspect hole was installed later to probably align with flow requirements for the new pump.

    • u/lukmly013 💾 (lemmy.sdf.org)
      link
      English
      266 months ago

      I found more info here (news.com.au).
      Also shows image of the pipe and:

      “[It] appears right now the pump was put in there, and it was probably malfunctioning because of the open pipe that she ended up in was supposed to be pushing water out.”

      • @lennybird@lemmy.world
        link
        fedilink
        English
        17
        edit-2
        6 months ago

        Fuck sake that was a hard read. That poor mother. I can’t even comprehend the purpose of that pipe. They describe it as a lazy river so I’m assuming it’s some sort of equalizer pipe to the other side. Water flows in one direction around the pool and I think what they’re saying is the flow of the river was reversed for whatever reason. There would be quite a strong amount of suction through there, even if it wasn’t a direct intake line to the pump.

        Edit: oh this is old news, months old. Looks like it was indeed an outlet:

        “Her poor little body was contorted when she was sucked into this hole and pipe 20 feet back. Her body was inside of the motor when she had to be extracted," he said. "They had to break up concrete in order to extract her, cut pipe. It was absolutely horrific.”

        Pump’s flow was reversed for whatever reason.

        Elsewhere I read the pump actually did have an entrapment system engaged and shut off, but by the time she blocked the pipe and sensors detected the obstruction, she was already wedged 20 feet into the pipe.

  • @lennybird@lemmy.world
    link
    fedilink
    English
    162
    edit-2
    6 months ago

    That poor child… And those poor ems workers who had to dig out her little body…

    I tagged along with my wife for a pool day at her friend’s house with our kids. I was swimming along near the wall of the pool when my foot was violently pulled into the vaccuum line. Really spooked me. It’s code for those suction lines to have a spring-loaded cover. This one didn’t. I luckily freed my foot and went to check the valves on the pump. All suction was routed to the vacuum line, none to skimmer.

    Some expensive pumps have an anti-entrapment system but most do not.

    I warned her to get that shit fixed ASAP…

    For commercial pools of this scale, there’s just no chance to resist.

    I own a pool now and I take all that shit very seriously. You don’t mess around with water.

    • @Passerby6497@lemmy.world
      link
      fedilink
      English
      556 months ago

      I still have nightmares from being a kid in a pool and getting stuck with my face basically at the water line because of something like that.

  • @assassin_aragorn@lemmy.world
    link
    fedilink
    896 months ago

    Sorry, what the fuck. This is a complete failure on engineering controls and safety. A safety analysis on an industrial plant would find something like this to be a major safety vulnerability that needs several redundant safeguards.

    Jesus fucking Christ.

  • Jeena
    link
    fedilink
    English
    746 months ago

    Same thing happened to my fiancés coworkers kid. The pipe sucked his arm in and got his head under water. They couldn’t get him out so they needed to wait until all water from the pool was drained. It was their only kid and already 12 or so.

      • Jeena
        link
        fedilink
        586 months ago

        Oh, I’m sorry I left it out, no, sadly he did not survive.

        • @dohpaz42@lemmy.world
          link
          fedilink
          English
          306 months ago

          Damn. I was hoping you would t say that. As a dad myself, I could t think of know a worse thing to happen — especially since one of my greatest fears is to die via drowning or suffocation. That breaks my heart for that family.

      • Jeena
        link
        fedilink
        116 months ago

        I was also thinking about that but I guess he was already dead when they found him under water.

      • @TheBraveSirRobbin@lemmy.world
        link
        fedilink
        36 months ago

        My guess would be that the first attempt to rescue would usually be to turn off the filter and / or attempt to jump in and pull them out. I would think by the point anyone would think of and be able to access something to breathe through it would be too late.

        This is all speculation on my point though, idk

  • @Forfaden@lemmy.world
    link
    fedilink
    English
    646 months ago

    I work as a pool maintenance technician in Texas. There are laws that are pretty strict for public pools for anti-entrapment drains

    From what I’ve been able to read and from what I’ve read from interviews, the pipe was like 6" wide and didn’t have a cover. I believe it was a wall return that she was sucked into. But it was plumbed backwards and so it was pulling water instead of pushing

    I work with multiple river pumps and they’re frequently the biggest pumps in the pump room. So the water they return is at a pretty high flow rate and none of them have a cover on the pressure side. The ones I work with have multiple openings of an inch or two

    But the main reason this happened was someone fucked up with plumbing the pump and used the discharge side for the pressure side. No idea how someone wouldn’t notice

    I think I read that they didn’t disclose that they were renovating and adding a river. No idea why it wasn’t looked at either. So, so, so many levels of failure lead to this

    • @bcgm3@lemmy.world
      link
      fedilink
      17
      edit-2
      6 months ago

      Dunno if it changes anything, but user224 posted this link elsewhere in this discussion, and it says the pipe was 30cm (almost a foot) in diameter – I’m no expert, but the photos in this and OP’s article seem to show an opening about that size to me. I only mention it because that seemed uncommonly large to me.

    • Jojo, Lady of the West
      link
      fedilink
      366 months ago

      It’s manslaughter. You kill someone with a machine, even if you weren’t trying to, it’s right up there next to murder.

  • D1G17AL
    link
    fedilink
    476 months ago

    Delta P is a scary phenomenon. Who else watched that terrifying video with the far too cheerful narrator?

  • @foggy@lemmy.world
    link
    fedilink
    40
    edit-2
    6 months ago

    There was a story on this shit on 60 minutes in the 90s. Maybe chronicle. Idk. Stories about people having their intestines ripped out of their assholes.

    Horrifying shit.

    Apparently not a universally solved issue?

    • @Burninator05@lemmy.world
      link
      fedilink
      346 months ago

      If there was only one pipe or doesn’t really matter if there is a screen or not. If the pipe had a cover she would have still been stuck on the bottom and no one likely would have been able to get her out of the water. If a second pipe had been there the pressure wouldn’t have built up enough to suck her in.

      • @alcoholicorn@lemmy.ml
        link
        fedilink
        566 months ago

        This is a solved engineering problem, they have screens that are shaped such that a person can’t cover it.

      • @lennybird@lemmy.world
        link
        fedilink
        English
        96 months ago

        Elsewhere I read the pump actually did have an entrapment system engaged and shut off, but by the time she blocked the pipe and sensors detected the obstruction, she was already wedged 20 feet into the pipe.

        In other words, if this had a simple grate and she blocked it with her body, the pump would’ve shut off almost immediately.

        The other problem is this hole was supposed to be an outlet, not an inlet. But the pump was reversed for whatever reason.

      • @Forfaden@lemmy.world
        link
        fedilink
        English
        46 months ago

        I work in the pool industry. From my understanding, she was sucked into a water return so there isn’t regulation requiring a cover

        It’s like being sucked into the end of a fire hose, there isn’t a cover because it’s supposed to pushing water out so a cover wouldn’t help

        If I remember right, the pool was recently renovated so I believe they plumbed it backwards. So the water was returning through a screen

  • @Daedskin@lemm.ee
    link
    fedilink
    346 months ago

    When I managed a pool, I remember the Virginia Graeme Baker act being something I was told about pretty early on; it was a prevalent enough of a thing that sometimes trying to start up my spa’s motor wouldn’t provide a clear enough suction, and the motor would shut off for safety. A properly managed pool should never have had this risk.

  • @Sam_Bass@lemmy.world
    link
    fedilink
    216 months ago

    So vacuum pipes are not required to have grates installed on them? If not for peoples safety than to at least prevent trash clogs

    • @brygphilomena@lemmy.world
      link
      fedilink
      96 months ago

      While there are significant regulations around intake pipes, including grates and/or having multiple intakes so that no single one can be completely obstructed to create a suction scenario where someone can be trapped, this particular pipe was found to be plumbed on the wrong side of the pump. It was sucking in water when it was supposed to be ejecting water.

      This is serious for the hotel chain, franchisee, installer/contractor, and inspector. This had to fail so many checks to have occurred. It wasn’t a chance occurrence for someone to be sucked in and seriously harmed or killed with the way this was plumbed; it was a matter of time when someone was going to be seriously injured or killed.

      Truly a tragedy, and I cannot for the life of me imagine the pain that family is going through right now.